WMA WMP 08 Single-handed butt point machine
Air-cooled single-handed impact point system for vehicle construction, tank construction, steel cabinet construction, sheet metal processing and wire industry
- Problem-free welding of all sheet metal
- galvanized sheets can be welded perfectly thanks to controlled current increase and controlled current decrease
- Air-cooled, equipped for external water cooling
- tools are easy to change thanks to standardized swivel connections
- only one plug each for welding power cable, control cable and water cooling
- reproducible welding results at all times thanks to built-in, automatic energy control
Microprocessor thyristor control
- constant current control
- seamless process monitoring
- Easy and convenient to operate
- all set parameters and process variables can be read at a glance
- welding parameters can only be changed by authorized personnel
- Configuration and program settings can be managed via a central PC
WMA WMS 108 Microprocessor thyristor controller
- 7 times
- 8 programs
- Built-in device
- Automatic mains frequency detection 50/60 Hz
- Power failure-proof storage of parameters
- "with/without power" switchover via button
Additional configuration parameters locked for users):
- Program selection
- Progressive contact
- Time of continuous contact
- Two-hand interlock (check)
- Interlock Start signal
- Current flow control
- Response threshold
- Current flow control
- Monitoring time
- Current flow control
- Power factor adjustment
- Delay 1st half-wave
External inputs (24V, DC stabilized and switching)
- Thermoswitch
- Thyristor temperature
- EMERGENCY OFF
- Start 1
- Start 2*
- Pressure contact
- Program 1*
- Program 2*
- Pre-stroke On
- Program interruption after hold-off time (only force)
- Two-hand interlock (check)*
* These functions can be activated or blocked via configuration parameters.
Nledoq H Aqxopfx Ac Dsk
External outputs (24V, DC unstable ± 20%; + switching, max. 5 W):
- Solenoid valve pre-stroke
- Welding solenoid valve
- Relay Advance contact
- Relay Ready for operation
Manufacturer: WMA
Type: WMP 08-01
Rated voltage: 400 V
Mains frequency: 50 Hz
Rated power (at 50% duty cycle) 22.5 kVA
Switch cabinet with PLC logo
PDF files under Documents tab
Further articles - new and used - can be found in our store!
International shipping costs on request!
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Air-cooled single-handed impact point system for vehicle construction, tank construction, steel cabinet construction, sheet metal processing and wire industry
- Problem-free welding of all sheet metal
- galvanized sheets can be welded perfectly thanks to controlled current increase and controlled current decrease
- Air-cooled, equipped for external water cooling
- tools are easy to change thanks to standardized swivel connections
- only one plug each for welding power cable, control cable and water cooling
- reproducible welding results at all times thanks to built-in, automatic energy control
Microprocessor thyristor control
- constant current control
- seamless process monitoring
- Easy and convenient to operate
- all set parameters and process variables can be read at a glance
- welding parameters can only be changed by authorized personnel
- Configuration and program settings can be managed via a central PC
WMA WMS 108 Microprocessor thyristor controller
- 7 times
- 8 programs
- Built-in device
- Automatic mains frequency detection 50/60 Hz
- Power failure-proof storage of parameters
- "with/without power" switchover via button
Additional configuration parameters locked for users):
- Program selection
- Progressive contact
- Time of continuous contact
- Two-hand interlock (check)
- Interlock Start signal
- Current flow control
- Response threshold
- Current flow control
- Monitoring time
- Current flow control
- Power factor adjustment
- Delay 1st half-wave
External inputs (24V, DC stabilized and switching)
- Thermoswitch
- Thyristor temperature
- EMERGENCY OFF
- Start 1
- Start 2*
- Pressure contact
- Program 1*
- Program 2*
- Pre-stroke On
- Program interruption after hold-off time (only force)
- Two-hand interlock (check)*
* These functions can be activated or blocked via configuration parameters.
Nledoq H Aqxopfx Ac Dsk
External outputs (24V, DC unstable ± 20%; + switching, max. 5 W):
- Solenoid valve pre-stroke
- Welding solenoid valve
- Relay Advance contact
- Relay Ready for operation
Manufacturer: WMA
Type: WMP 08-01
Rated voltage: 400 V
Mains frequency: 50 Hz
Rated power (at 50% duty cycle) 22.5 kVA
Switch cabinet with PLC logo
PDF files under Documents tab
Further articles - new and used - can be found in our store!
International shipping costs on request!
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Tài liệu
Nhà cung cấp
Lưu ý: Đăng ký miễn phí hoặc đăng nhập, để truy cập tất cả thông tin.
Đã đăng ký từ: 2008
Gửi yêu cầu
Điện thoại & Fax
+49 2862 ... quảng cáo
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi