Bơm đôi chạy khôWilo
DL-E 100/145-11/2-S1
Bơm đôi chạy khô
Wilo
DL-E 100/145-11/2-S1
VB chưa bao gồm thuế GTGT
6.640 €
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Hình ảnh cho thấy
Hiển thị bản đồ
Thông tin về máy móc
- Tên máy:
- Bơm đôi chạy khô
- Nhà sản xuất:
- Wilo
- Mô hình:
- DL-E 100/145-11/2-S1
- Tình trạng:
- tốt (đã qua sử dụng)
Giá & Vị trí
VB chưa bao gồm thuế GTGT
6.640 €
- Vị trí:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A18920911
- Số tham chiếu:
- 33806
- Cập nhật:
- lần cuối vào ngày 27.11.2025
Mô tả
Wilo DL-E 100/145-11/2-S1 Glanded double pump
Glanded double pump in inline design for pipe installation or foundation installation with integrated frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled glanded double pump in inline design with flange connection and automatic power adjustment
Application
Pumping of heating water (in accordance with VDI 2035), cold water and water-glycol mixtures without abrasive substances in heating, cold water and cooling systems.
Equipment/function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Actuator mode (n=constant)
Manual operating level
Setting the differential pressure setpoint
Setting the speed (manual control mode)
Setting the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Error acknowledgement
External control functions
“Priority Off” control input
“External pump replacement” control input (only effective for dual pump operation)
Analog input 0-10 V, 0-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal of the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal of the pressure sensor
Message and display functions
Collective fault message SSM
Collective operation message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to the building automation system
Kedpfx Aowbqrtoc Djfa
Safety functions
Full motor protection with integrated tripping electronics
Access lock
Double pump management (double pump or 2 x single pump) 2 x single pump)
Main/standby mode (automatic fault switchover)
Main/standby mode Pump replacement after 24 hours
Add-on mode
Add-on mode (efficiency-optimized peak load switch-on and switch-off)
Your benefits
Energy saving thanks to integrated electronic power adjustment
Simple operation thanks to green button technology and display
Various operating modes: Main/standby mode and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (KLF) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Nominal motor power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Interference emission EN 61800-3
Interference immunity EN 61800-3
Insulation class: F
Protection class motor: IP55
Motor protection: KLF integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: € 29,006.25
Find more new and used items in our store!
International shipping costs on request!
Glanded double pump in inline design for pipe installation or foundation installation with integrated frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled glanded double pump in inline design with flange connection and automatic power adjustment
Application
Pumping of heating water (in accordance with VDI 2035), cold water and water-glycol mixtures without abrasive substances in heating, cold water and cooling systems.
Equipment/function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Actuator mode (n=constant)
Manual operating level
Setting the differential pressure setpoint
Setting the speed (manual control mode)
Setting the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Error acknowledgement
External control functions
“Priority Off” control input
“External pump replacement” control input (only effective for dual pump operation)
Analog input 0-10 V, 0-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal of the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal of the pressure sensor
Message and display functions
Collective fault message SSM
Collective operation message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to the building automation system
Kedpfx Aowbqrtoc Djfa
Safety functions
Full motor protection with integrated tripping electronics
Access lock
Double pump management (double pump or 2 x single pump) 2 x single pump)
Main/standby mode (automatic fault switchover)
Main/standby mode Pump replacement after 24 hours
Add-on mode
Add-on mode (efficiency-optimized peak load switch-on and switch-off)
Your benefits
Energy saving thanks to integrated electronic power adjustment
Simple operation thanks to green button technology and display
Various operating modes: Main/standby mode and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (KLF) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Nominal motor power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Interference emission EN 61800-3
Interference immunity EN 61800-3
Insulation class: F
Protection class motor: IP55
Motor protection: KLF integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: € 29,006.25
Find more new and used items in our store!
International shipping costs on request!
Nhà cung cấp
Lưu ý: Đăng ký miễn phí hoặc đăng nhập, để truy cập tất cả thông tin.
Gửi yêu cầu
Điện thoại & Fax
+49 2862 ... quảng cáo
Những tin rao vặt này cũng có thể bạn quan tâm.
Quảng cáo nhỏ
Nordhorn
9.517 km
Hệ thống băng tải con lăn điều khiển
SSI Schäfer
SSI Schäfer
Quảng cáo nhỏ
Oftersheim
9.520 km
Máy bơm ly tâm
GrundfosCR 60 20 A-F-A-BBUE Model B500002P39447
GrundfosCR 60 20 A-F-A-BBUE Model B500002P39447
Quảng cáo nhỏ
Berlin
9.112 km
Máy bơm ly tâm
Alfa LavalLKH 85/226 DMS
Alfa LavalLKH 85/226 DMS
Quảng cáo nhỏ
Klam bei Grein
9.111 km
Hệ thống làm đầy vít làm đầy dăm gỗ
Löttner Maschinenbau
Löttner Maschinenbau
Quảng cáo nhỏ
Wiefelstede
9.429 km
Động cơ điện 160 kW 1485 vòng/phút
LoherAMGA-315MD-04A
LoherAMGA-315MD-04A
Quảng cáo nhỏ
Frankenberg/Sa.
9.170 km
Máy bơm ETANORM G 150-250
KSBETANORM G 150-250 G10
KSBETANORM G 150-250 G10
Quảng cáo nhỏ
Leipzig
9.202 km
Linearmotor
Leomotor A/SKC 218B159 - LM 2000 - 12630
Leomotor A/SKC 218B159 - LM 2000 - 12630
Quảng cáo nhỏ
Piskorzów
8.887 km
Động cơ điện
ABBM3BP 400LKB 4 IMB3/IM1001 630 kW
ABBM3BP 400LKB 4 IMB3/IM1001 630 kW
Quảng cáo nhỏ
Luckenwalde
9.132 km
Hệ thống băng tải chuyển thanh
PROTONBar Transferred Conveyor
PROTONBar Transferred Conveyor
Quảng cáo nhỏ
Klettgau
9.586 km
Bơm chân không
SchmalzWK-JU-65-3000-SRA-100-500-VSL
SchmalzWK-JU-65-3000-SRA-100-500-VSL
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi































































































