Phòng mô phỏng khí hậu Walk-inTIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
Phòng mô phỏng khí hậu Walk-in
TIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Hình ảnh cho thấy
Hiển thị bản đồ
Thông tin về máy móc
Giá & Vị trí
- Vị trí:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A18478886
- Số tham chiếu:
- 23515
- Cập nhật:
- lần cuối vào ngày 12.03.2026
Mô tả
TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
Nwedpsvx S Hhofx Albjf
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
Nwedpsvx S Hhofx Albjf
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Những tin rao vặt này cũng có thể bạn quan tâm.
Quảng cáo nhỏ
Olsztyn
8.617 km
Thiết bị phòng thí nghiệm - Bộ
Shimadzu, Wyposażenie laboratorium
Shimadzu, Wyposażenie laboratorium
Quảng cáo nhỏ
Möckmühl
9.470 km
Máy ép nhiệt
IlligUA 155 G Solo/ BE
IlligUA 155 G Solo/ BE
Quảng cáo nhỏ
Skarżysko-Kamienna
8.625 km
Lò điện polymer hóa
Romer PolandSL - 2020
Romer PolandSL - 2020
Quảng cáo nhỏ
Gelnhausen
9.457 km
Máy hút chân không Pfeiffer Okta 6000
Pfeiffer VacuumOkta 6000
Pfeiffer VacuumOkta 6000
Quảng cáo nhỏ
Wuppertal
9.557 km
Báo chí đốm
HESSMERT160 EST
HESSMERT160 EST
Quảng cáo nhỏ
Zuchwil
9.663 km
Lò xử lý nhiệt retort
MUT360/400-1150
MUT360/400-1150
Quảng cáo nhỏ
Enschede
9.542 km
Máy cắt laser ống
Bodor K2
Bodor K2
Quảng cáo nhỏ
Borken
9.559 km
Tăng cường rễ blower rễ máy bơm pít tông
PfeifferOkta 2000 A M
PfeifferOkta 2000 A M
Quảng cáo nhỏ
Meiningen
9.356 km
Lò nung buồng tuần hoàn không khí 250°C
Ingenieurbüro Klein mit Umluft, NanodacUK 8820-250
Ingenieurbüro Klein mit Umluft, NanodacUK 8820-250
Quảng cáo nhỏ
Đức
9.339 km
Lò đối lưu
NaberthermN500/65HA
NaberthermN500/65HA
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi