Thiết bị kiểm tra sốc nhiệtRS-Simulatoren
ST2K320/45 K
Thiết bị kiểm tra sốc nhiệt
RS-Simulatoren
ST2K320/45 K
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Thông tin về máy móc
- Tên máy:
- Thiết bị kiểm tra sốc nhiệt
- Nhà sản xuất:
- RS-Simulatoren
- Mô hình:
- ST2K320/45 K
- Tình trạng:
- rất tốt (đã qua sử dụng)
Giá & Vị trí
- Vị trí:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A22185487
- Số tham chiếu:
- 24112
- Cập nhật:
- lần cuối vào ngày 23.06.2026
Mô tả
RS Simulators
Type: ST2K320/45 K
Nwsdpfx Aozgbutjmgsh
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Type: ST2K320/45 K
Nwsdpfx Aozgbutjmgsh
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Những tin rao vặt này cũng có thể bạn quan tâm.
Quảng cáo nhỏ
Borken
9.555 km
Thiết bị kiểm tra sốc nhiệt
RS-SimulatorenST2K320/45
RS-SimulatorenST2K320/45
Quảng cáo nhỏ
Wesel
9.582 km
Máy hoàn thiện rung
ERBAYE 60 Separierstrecke
ERBAYE 60 Separierstrecke
Quảng cáo nhỏ
Mandres-la-Côte
9.792 km
Máy sấy tròn
ROSLER PARKER ROTOFINISHS 20
ROSLER PARKER ROTOFINISHS 20
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi