GBS Prüfpuls rev3 pulse generator for long-term insulation testing up to 6 nFGBS Elektronik
rev3 Isolationstests bis 6nF
GBS Prüfpuls rev3 pulse generator for long-term insulation testing up to 6 nF
GBS Elektronik
rev3 Isolationstests bis 6nF
VB chưa bao gồm thuế GTGT
3.781 €
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Dữ liệu cơ bản
Giá & Vị trí
VB chưa bao gồm thuế GTGT
3.781 €
- Vị trí:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A17569468
- Số tham chiếu:
- 21007
- Cập nhật:
- lần cuối vào ngày 21.10.2026
Mô tả
GBS Prüfpuls rev3 Pulse generator for long-term insulation tests
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
Crjdpfeu Egz Rox Anlji
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
Crjdpfeu Egz Rox Anlji
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Nhà cung cấp
Lưu ý: Đăng ký miễn phí hoặc đăng nhập, để truy cập tất cả thông tin.
Đã đăng ký từ: 2008
532 Quảng cáo trực tuyến
Gửi yêu cầu
Điện thoại & Fax
+49 2862 ... quảng cáo
Những tin rao vặt này cũng có thể bạn quan tâm.
Thành công
Tin nhắn của bạn đã được gửi đi.
Quảng cáo nhỏ
Wiefelstede
9.429 km
Băng ghế dự bị 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi