Mô tả
Binder
BINDER KB 720 Refrigerated Incubator with P Plus Package
Battery Test Chamber EUCAR 5, CO₂ Extinguishing System
Device Description:
For sale is a BINDER KB 720 (E6) refrigerated incubator, year of manufacture 2022, equipped with the upgraded safety and performance test package “P Plus.”
This is not a standard laboratory incubator, but rather a high-end safety test chamber specifically designed for aging, performance, and safety testing of lithium-ion energy storage systems.
The device is fully functional and has been tested. It originally sustained a transport-related housing damage, which has been professionally repaired and repainted.
Technically flawless – visually in very good condition
100% operational – no limitations
Price advantage: €1,000 cheaper than comparable units
Special Value Added:
The unit is designed to reliably detect, monitor, and safely contain critical battery events – up to EUCAR hazard level 5 (fire/flames, no explosion).
What exactly can the device do? (Item 2 – Performance & Application)
- Aging tests on lithium-ion cells
- Performance tests (charge/discharge cycles at temperature)
- Long-term temperature runs and thermal cycling tests
- Testing of unpowered and cyclical powered cells
- Reproducible, precise temperature control throughout the entire chamber
- Safe testing under realistic thermal conditions
- Test environment for R&D, automotive, e-mobility, and energy storage technology
Suitable for:
- Battery & cell manufacturers
- Research and development laboratories
- Test labs & safety testing
- Automotive / E-mobility / Energy storage sectors
The P Plus package turns the KB 720 into a genuine battery safety test cabinet:
Integrated Safety Features:
- Automatic & manual CO₂ fire suppression system
- Smoke detector with optical and acoustic alarm
- Mechanical double-door locking (secure containment)
- Spark protection inside chamber
- Exhaust port with reversible overpressure valve
- Connections for external inertization (e.g., nitrogen)
- Emergency stop / manual trigger of suppression system
- Cable feedthroughs for charging and measurement cables
Result:
The device is designed for testing lithium-ion cells up to EUCAR hazard level 5, where fire or flames may occur, but without explosion or uncontrolled propagation.
This is not an abuse or destruction testing device, but a compliant, safe test chamber for real-world operational and fault scenarios.
Technical Key Data:
Temperature range: –10 °C to +100 °C
Internal volume: approx. 698 liters
Shelves: 4 × stainless steel
Max. load per shelf: 45 kg
Max. overall load: 100 kg
Electrical Data:
Power supply: 200–240 V AC
Frequency: 50 / 60 Hz
Phase: single-phase
Power consumption: approx. 2.1 kW
Fusing: 16 A
Refrigerant: R134a
Protection class: IP 20
Dimensions & Weight:
External (W × H × D): approx. 1250 × 1950 × 900 mm
Internal (W × H × D): approx. 970 × 1250 × 576 mm
In summary – why this device is special:
- Genuine battery safety test cabinet
- EUCAR hazard level 5 capable
Redpfxoyyw E Ro Ah Dor
- Integrated CO₂ extinguishing system
- Large chamber (≈700 l)
- High market and resale value
Weight: approx. 285–300 kg
Documents & Downloads
Condition: used
Scope of delivery: (see photo)
(Specifications subject to change and errors reserved!)
Further questions? Please feel free to contact us by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
BINDER KB 720 Refrigerated Incubator with P Plus Package
Battery Test Chamber EUCAR 5, CO₂ Extinguishing System
Device Description:
For sale is a BINDER KB 720 (E6) refrigerated incubator, year of manufacture 2022, equipped with the upgraded safety and performance test package “P Plus.”
This is not a standard laboratory incubator, but rather a high-end safety test chamber specifically designed for aging, performance, and safety testing of lithium-ion energy storage systems.
The device is fully functional and has been tested. It originally sustained a transport-related housing damage, which has been professionally repaired and repainted.
Technically flawless – visually in very good condition
100% operational – no limitations
Price advantage: €1,000 cheaper than comparable units
Special Value Added:
The unit is designed to reliably detect, monitor, and safely contain critical battery events – up to EUCAR hazard level 5 (fire/flames, no explosion).
What exactly can the device do? (Item 2 – Performance & Application)
- Aging tests on lithium-ion cells
- Performance tests (charge/discharge cycles at temperature)
- Long-term temperature runs and thermal cycling tests
- Testing of unpowered and cyclical powered cells
- Reproducible, precise temperature control throughout the entire chamber
- Safe testing under realistic thermal conditions
- Test environment for R&D, automotive, e-mobility, and energy storage technology
Suitable for:
- Battery & cell manufacturers
- Research and development laboratories
- Test labs & safety testing
- Automotive / E-mobility / Energy storage sectors
The P Plus package turns the KB 720 into a genuine battery safety test cabinet:
Integrated Safety Features:
- Automatic & manual CO₂ fire suppression system
- Smoke detector with optical and acoustic alarm
- Mechanical double-door locking (secure containment)
- Spark protection inside chamber
- Exhaust port with reversible overpressure valve
- Connections for external inertization (e.g., nitrogen)
- Emergency stop / manual trigger of suppression system
- Cable feedthroughs for charging and measurement cables
Result:
The device is designed for testing lithium-ion cells up to EUCAR hazard level 5, where fire or flames may occur, but without explosion or uncontrolled propagation.
This is not an abuse or destruction testing device, but a compliant, safe test chamber for real-world operational and fault scenarios.
Technical Key Data:
Temperature range: –10 °C to +100 °C
Internal volume: approx. 698 liters
Shelves: 4 × stainless steel
Max. load per shelf: 45 kg
Max. overall load: 100 kg
Electrical Data:
Power supply: 200–240 V AC
Frequency: 50 / 60 Hz
Phase: single-phase
Power consumption: approx. 2.1 kW
Fusing: 16 A
Refrigerant: R134a
Protection class: IP 20
Dimensions & Weight:
External (W × H × D): approx. 1250 × 1950 × 900 mm
Internal (W × H × D): approx. 970 × 1250 × 576 mm
In summary – why this device is special:
- Genuine battery safety test cabinet
- EUCAR hazard level 5 capable
Redpfxoyyw E Ro Ah Dor
- Integrated CO₂ extinguishing system
- Large chamber (≈700 l)
- High market and resale value
Weight: approx. 285–300 kg
Documents & Downloads
Condition: used
Scope of delivery: (see photo)
(Specifications subject to change and errors reserved!)
Further questions? Please feel free to contact us by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Những tin rao vặt này cũng có thể bạn quan tâm.
Quảng cáo nhỏ
Borken
9.555 km
Tủ kiểm tra EUCAR 5, hệ thống chữa cháy CO₂
Binder Batterie-TestschrankKB 720 Kühlinkubator mit Paket P Plus
Binder Batterie-TestschrankKB 720 Kühlinkubator mit Paket P Plus
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi