Tủ kiểm tra EUCAR 5, hệ thống chữa cháy CO₂Binder Batterie-Testschrank
KB 720 Kühlinkubator mit Paket P Plus
Tủ kiểm tra EUCAR 5, hệ thống chữa cháy CO₂
Binder Batterie-Testschrank
KB 720 Kühlinkubator mit Paket P Plus
Năm sản xuất
2022
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Hình ảnh cho thấy
Hiển thị bản đồ
Thông tin về máy móc
Giá & Vị trí
- Vị trí:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A20746972
- Số tham chiếu:
- 24924
- Cập nhật:
- lần cuối vào ngày 12.12.2025
Mô tả
Binder
BINDER KB 720 Refrigerated Incubator with P Plus Package
– Battery Test Chamber EUCAR 5, CO₂ Extinguishing System
Device Description:
For sale is a BINDER KB 720 (E6) refrigerated incubator, year of manufacture 2022, equipped with the advanced safety and performance test package “P Plus”.
This device is not a standard laboratory incubator but a high-quality safety test chamber, specifically designed for aging, performance, and safety testing of lithium-ion energy storage systems.
Key Added Value:
The unit is designed to reliably detect, monitor, and contain critical battery events safely—including up to EUCAR Hazard Level 5 (fire/flames, no explosion).
What can the device do specifically? (Section 2 – Performance & Application)
– Conduct aging tests on lithium-ion cells
– Performance tests (charge/discharge cycles under temperature)
– Continuous temperature runs and thermal cycling tests
– Testing of non-energized and cyclically energized cells
Fsdex Hf A Ropfx Aatopr
– Reproducible, precise temperature control throughout the entire usable space
– Safe execution of tests under realistic thermal conditions
– Test environment for R&D, automotive, e-mobility, and energy storage technology
Suitable for:
– Battery & cell manufacturers
– Research and development laboratories
– Test laboratories & safety testing
– Automotive / e-mobility / energy storage sectors
The P Plus package transforms the KB 720 into a genuine battery safety test cabinet:
Integrated Safety Features:
– Automatic & manual CO₂ fire suppression system
– Smoke detector with optical & acoustic alarm
– Mechanical double door locking (secure containment)
– Spark protection in the interior compartment
– Exhaust connection with reversible overpressure flap
– Connections for external inerting (e.g., nitrogen)
– Emergency stop / manual release of extinguishing system
– Ports for charging and measurement cables
Result:
The device is designed for testing lithium-ion cells up to EUCAR Hazard Level 5, where fire or flames can occur, but not explosion or uncontrolled propagation. This is not an abuse or destruction test device, but a secure, standard-compliant test chamber for real-world operating and fault scenarios.
Technical Core Data:
– Temperature range: –5 °C to +100 °C
– Interior volume: approx. 698 liters
– Shelves: 4 × stainless steel
– Max. load per shelf: 45 kg
– Max. total load: 100 kg
Electrical Data:
– Mains connection: 200–240 V AC
– Frequency: 50/60 Hz
– Phases: single-phase
– Power consumption: approx. 2.1 kW
– Circuit protection: 16 A
– Refrigerant: R134a
– Protection class: IP 20
Dimensions & Weight:
– External (W × H × D): approx. 1250 × 1950 × 900 mm
– Internal (W × H × D): approx. 970 × 1250 × 576 mm
In short – why is this device special?
– Genuine battery safety test chamber
– Suitable for EUCAR Hazard Level 5
– Integrated CO₂ extinguishing system
– Large chamber (≈700 l)
– High market value & resale attractiveness
– Weight: approx. 285–300 kg
– Condition: used
– Scope of delivery: (see image)
(Technical data subject to change and errors excepted!)
For further questions, we are happy to answer your call.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
BINDER KB 720 Refrigerated Incubator with P Plus Package
– Battery Test Chamber EUCAR 5, CO₂ Extinguishing System
Device Description:
For sale is a BINDER KB 720 (E6) refrigerated incubator, year of manufacture 2022, equipped with the advanced safety and performance test package “P Plus”.
This device is not a standard laboratory incubator but a high-quality safety test chamber, specifically designed for aging, performance, and safety testing of lithium-ion energy storage systems.
Key Added Value:
The unit is designed to reliably detect, monitor, and contain critical battery events safely—including up to EUCAR Hazard Level 5 (fire/flames, no explosion).
What can the device do specifically? (Section 2 – Performance & Application)
– Conduct aging tests on lithium-ion cells
– Performance tests (charge/discharge cycles under temperature)
– Continuous temperature runs and thermal cycling tests
– Testing of non-energized and cyclically energized cells
Fsdex Hf A Ropfx Aatopr
– Reproducible, precise temperature control throughout the entire usable space
– Safe execution of tests under realistic thermal conditions
– Test environment for R&D, automotive, e-mobility, and energy storage technology
Suitable for:
– Battery & cell manufacturers
– Research and development laboratories
– Test laboratories & safety testing
– Automotive / e-mobility / energy storage sectors
The P Plus package transforms the KB 720 into a genuine battery safety test cabinet:
Integrated Safety Features:
– Automatic & manual CO₂ fire suppression system
– Smoke detector with optical & acoustic alarm
– Mechanical double door locking (secure containment)
– Spark protection in the interior compartment
– Exhaust connection with reversible overpressure flap
– Connections for external inerting (e.g., nitrogen)
– Emergency stop / manual release of extinguishing system
– Ports for charging and measurement cables
Result:
The device is designed for testing lithium-ion cells up to EUCAR Hazard Level 5, where fire or flames can occur, but not explosion or uncontrolled propagation. This is not an abuse or destruction test device, but a secure, standard-compliant test chamber for real-world operating and fault scenarios.
Technical Core Data:
– Temperature range: –5 °C to +100 °C
– Interior volume: approx. 698 liters
– Shelves: 4 × stainless steel
– Max. load per shelf: 45 kg
– Max. total load: 100 kg
Electrical Data:
– Mains connection: 200–240 V AC
– Frequency: 50/60 Hz
– Phases: single-phase
– Power consumption: approx. 2.1 kW
– Circuit protection: 16 A
– Refrigerant: R134a
– Protection class: IP 20
Dimensions & Weight:
– External (W × H × D): approx. 1250 × 1950 × 900 mm
– Internal (W × H × D): approx. 970 × 1250 × 576 mm
In short – why is this device special?
– Genuine battery safety test chamber
– Suitable for EUCAR Hazard Level 5
– Integrated CO₂ extinguishing system
– Large chamber (≈700 l)
– High market value & resale attractiveness
– Weight: approx. 285–300 kg
– Condition: used
– Scope of delivery: (see image)
(Technical data subject to change and errors excepted!)
For further questions, we are happy to answer your call.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Nhà cung cấp
Lưu ý: Đăng ký miễn phí hoặc đăng nhập, để truy cập tất cả thông tin.
Đã đăng ký từ: 2012
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi