Mô tả
Weiss
Type: WT3-1000/40
Weiss temperature test chamber with S!MCON / 32 control system, water-cooled
Control panel: “Touch panel”
The “Touch panel” control panel allows all control and operating commands to be executed simply by touching the function symbols.
Adjustable feet
To compensate for unevenness in the floor and to ensure sufficient ventilation of the machine, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthrough installed as standard
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 990 liters
Test chamber dimensions: height 950 mm, width 1100 mm, depth 950 mm
External dimensions: height 2000 mm, width 1415 mm, depth 2105 mm
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 4500 W
Data for operation:
Test chamber lighting: halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 22.0 A, rated power 11.5 kW
Fuse on customer side: 32 A slow-blow
Sound pressure level approx.
Lhedpszgbt Nofx Agvsh
measured at a distance of 1 m from the front, 1 m height: 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Type: WT3-1000/40
Weiss temperature test chamber with S!MCON / 32 control system, water-cooled
Control panel: “Touch panel”
The “Touch panel” control panel allows all control and operating commands to be executed simply by touching the function symbols.
Adjustable feet
To compensate for unevenness in the floor and to ensure sufficient ventilation of the machine, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthrough installed as standard
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 990 liters
Test chamber dimensions: height 950 mm, width 1100 mm, depth 950 mm
External dimensions: height 2000 mm, width 1415 mm, depth 2105 mm
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 4500 W
Data for operation:
Test chamber lighting: halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 22.0 A, rated power 11.5 kW
Fuse on customer side: 32 A slow-blow
Sound pressure level approx.
Lhedpszgbt Nofx Agvsh
measured at a distance of 1 m from the front, 1 m height: 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi