Weiss
Type: WKL 100/40
Climate test chamber, air-cooled
with humidity control, -40 to +180°C
Specifications for temperature tests:
Temperature range: -40 to +180°C
Temperature uniformity after stabilization:
Temporal temperature fluctuation in the center of the usable space: ±0.3 to ±1 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature change rate:
Heating: 3.5 K/min
Kedpfexxtuiex Ahxedw
Cooling: 5 K/min
Heat compensation: max. 1,100 W
Specifications for climate (humidity) tests:
Humidification system data
Tank capacity: approx. 13 l
Water quality: Demineralized
pH value: 6 – 7
Conductivity: max. 20 µS/cm
Water consumption at constant +40°C, 92% r.h.: 2 l / 24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.h.
Temperature and humidity deviations (after stabilization):
Temporal temperature fluctuation in the chamber center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation in the chamber center: ±1 to ±3% r.h.
Mechanical load data:
Maximum floor load in test chamber: 25 kg
Per shelf: 10 kg
Total rack load: 50 kg
Right-side port: 50 mm ∅
Left-side port: 50 mm ∅
Interfaces: Ethernet (RJ45), USB
Operating data:
Chamber lighting: Halogen bulb, 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 3.0 kW
Rated current: 13.0 A
Site-side fuse: 16A slow-blow
Protection class:
Control cabinet IP 22, control panel IP 54
Heat output, air-cooled chambers:
Maximum heat output to environment: 2,000 W
Noise measurement:
Sound pressure level (free field measurement, 1 m distance in front, 1.6 m height):
approx. 56 dB(A)
Test chamber volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R-452a
For your safety as a buyer, please note the following information:
The following actions are performed on all chambers we offer prior to sale:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and descriptions reserved!)
We are happy to answer further questions by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Type: WKL 100/40
Climate test chamber, air-cooled
with humidity control, -40 to +180°C
Specifications for temperature tests:
Temperature range: -40 to +180°C
Temperature uniformity after stabilization:
Temporal temperature fluctuation in the center of the usable space: ±0.3 to ±1 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature change rate:
Heating: 3.5 K/min
Kedpfexxtuiex Ahxedw
Cooling: 5 K/min
Heat compensation: max. 1,100 W
Specifications for climate (humidity) tests:
Humidification system data
Tank capacity: approx. 13 l
Water quality: Demineralized
pH value: 6 – 7
Conductivity: max. 20 µS/cm
Water consumption at constant +40°C, 92% r.h.: 2 l / 24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.h.
Temperature and humidity deviations (after stabilization):
Temporal temperature fluctuation in the chamber center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation in the chamber center: ±1 to ±3% r.h.
Mechanical load data:
Maximum floor load in test chamber: 25 kg
Per shelf: 10 kg
Total rack load: 50 kg
Right-side port: 50 mm ∅
Left-side port: 50 mm ∅
Interfaces: Ethernet (RJ45), USB
Operating data:
Chamber lighting: Halogen bulb, 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 3.0 kW
Rated current: 13.0 A
Site-side fuse: 16A slow-blow
Protection class:
Control cabinet IP 22, control panel IP 54
Heat output, air-cooled chambers:
Maximum heat output to environment: 2,000 W
Noise measurement:
Sound pressure level (free field measurement, 1 m distance in front, 1.6 m height):
approx. 56 dB(A)
Test chamber volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R-452a
For your safety as a buyer, please note the following information:
The following actions are performed on all chambers we offer prior to sale:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and descriptions reserved!)
We are happy to answer further questions by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Nhà cung cấp
Lưu ý: Đăng ký miễn phí hoặc đăng nhập, để truy cập tất cả thông tin.
Đã đăng ký từ: 2012
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi