Tủ kiểm tra khí hậu, dung tích 990 lítWeiss –40…+180 °C
WK11-1000/40 mit Zander K-MT 2
Tủ kiểm tra khí hậu, dung tích 990 lít
Weiss –40…+180 °C
WK11-1000/40 mit Zander K-MT 2
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Hình ảnh cho thấy
Hiển thị bản đồ
Thông tin về máy móc
- Nhà sản xuất:
- Weiss –40…+180 °C
- Mô hình:
- WK11-1000/40 mit Zander K-MT 2
- Tình trạng:
- rất tốt (đã qua sử dụng)
Giá & Vị trí
- Vị trí:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A20761877
- Số tham chiếu:
- 24929
- Cập nhật:
- lần cuối vào ngày 15.12.2025
Mô tả
Weiss
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with integrated Zander K-MT 2 steam humidification unit. This unit is suitable for precise temperature and humidity testing of components, assemblies, and devices. Ideal for applications in industry, development, quality assurance, and research.
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
- Temperature range: -40°C to +180°C
- Temporal temperature fluctuation in the center of the usable space: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Rate of temperature change:
* Heating: 4 K/min
* Cooling: 3 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % RH
- Temporal temperature fluctuation in the center of the usable space: ±0.1 to ±0.3 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temporal humidity fluctuation in the center of the usable space: ±1 to ±3 % RH
- Heat compensation:
* In the range from +25°C to +95°C
* At relative humidity up to 90%: 500 W
Specifications for Humidification System:
- Reservoir capacity: 20 L
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 µS/cm3
- Water consumption at constant +40°C, 92 % RH: 21/24 h
- Temperature gradient (according to IEC 60068-3-5): 1 to 2 K
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Hfodpfx Aex Hxkzeatjr
Test chamber volume: approx. 990 liters
Rated voltage: 3/N / PE AC 400 V + 10% 50 Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
For your peace of mind as a buyer, please note the following information:
The following actions are performed on all chambers we offer before sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
Should you have further questions, we are happy to answer them by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with integrated Zander K-MT 2 steam humidification unit. This unit is suitable for precise temperature and humidity testing of components, assemblies, and devices. Ideal for applications in industry, development, quality assurance, and research.
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
- Temperature range: -40°C to +180°C
- Temporal temperature fluctuation in the center of the usable space: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Rate of temperature change:
* Heating: 4 K/min
* Cooling: 3 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % RH
- Temporal temperature fluctuation in the center of the usable space: ±0.1 to ±0.3 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temporal humidity fluctuation in the center of the usable space: ±1 to ±3 % RH
- Heat compensation:
* In the range from +25°C to +95°C
* At relative humidity up to 90%: 500 W
Specifications for Humidification System:
- Reservoir capacity: 20 L
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 µS/cm3
- Water consumption at constant +40°C, 92 % RH: 21/24 h
- Temperature gradient (according to IEC 60068-3-5): 1 to 2 K
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Hfodpfx Aex Hxkzeatjr
Test chamber volume: approx. 990 liters
Rated voltage: 3/N / PE AC 400 V + 10% 50 Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
For your peace of mind as a buyer, please note the following information:
The following actions are performed on all chambers we offer before sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
Should you have further questions, we are happy to answer them by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Nhà cung cấp
Lưu ý: Đăng ký miễn phí hoặc đăng nhập, để truy cập tất cả thông tin.
Đã đăng ký từ: 2012
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi