Buồng thử sốc nhiệt Heraeus +50°C đến +220°C, -65°C đến +70°C, model HT 7012 S2Vötsch
Heraeus Schocktestkammer
Buồng thử sốc nhiệt Heraeus +50°C đến +220°C, -65°C đến +70°C, model HT 7012 S2
Vötsch
Heraeus Schocktestkammer
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Dữ liệu cơ bản
Giá & Vị trí
- Vị trí:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A22148082
- Số tham chiếu:
- 23355
- Cập nhật:
- lần cuối vào ngày 15.10.2026
Mô tả
Heraeus
Type: HT 7012 S2
Temperature shock test chamber, water-cooled
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 2 K/min
Cooling 3 K/min
Isdpozd R Uwofx Ankotn
Test chamber volume 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -80°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Type: HT 7012 S2
Temperature shock test chamber, water-cooled
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 2 K/min
Cooling 3 K/min
Isdpozd R Uwofx Ankotn
Test chamber volume 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -80°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Những tin rao vặt này cũng có thể bạn quan tâm.