Tủ thử nghiệm nhiệt độ 680 lítHeraeus Vötsch
VLM 3068/S -30 °C bis +125 °C
Tủ thử nghiệm nhiệt độ 680 lít
Heraeus Vötsch
VLM 3068/S -30 °C bis +125 °C
Năm sản xuất
2010
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Thông tin về máy móc
- Tên máy:
- Tủ thử nghiệm nhiệt độ 680 lít
- Nhà sản xuất:
- Heraeus Vötsch
- Mô hình:
- VLM 3068/S -30 °C bis +125 °C
- Năm sản xuất:
- 2010
- Tình trạng:
- rất tốt (đã qua sử dụng)
Giá & Vị trí
- Vị trí:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A22185287
- Số tham chiếu:
- 23960
- Cập nhật:
- lần cuối vào ngày 23.06.2026
Mô tả
Here, we offer a Heraeus Vötsch temperature testing chamber.
Vötsch temperature testing chamber, test cabinet VLM 3068/S, air-cooled
(top-loading test chambers for construction materials)
Control panel
The control panel is mounted on a console on the temperature testing chamber. All control and operating commands can be initiated by simply touching the function symbols. The operating manual for the control panel is included.
Main switch
The main switch is located at the front of the temperature testing chamber.
Air handling unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control.
In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air guide plates on the long sides.
Feedthroughs
The temperature testing chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber.
Feedthrough at the front: 2 x 82 mm diameter, at the rear: 1 x 85 mm diameter
Internal dimensions: width 2000 mm, depth 570 mm, height 600 mm
External dimensions: width 3000 mm, depth 870 mm, height 1060 mm
Technical data:
Data for mechanical load:
max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Lsdezgbmiopfx Aavsac
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW, rated current 9 A
Fuse on customer side: 16A, slow-blow
Temperature testing chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement: sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Vötsch temperature testing chamber, test cabinet VLM 3068/S, air-cooled
(top-loading test chambers for construction materials)
Control panel
The control panel is mounted on a console on the temperature testing chamber. All control and operating commands can be initiated by simply touching the function symbols. The operating manual for the control panel is included.
Main switch
The main switch is located at the front of the temperature testing chamber.
Air handling unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control.
In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air guide plates on the long sides.
Feedthroughs
The temperature testing chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber.
Feedthrough at the front: 2 x 82 mm diameter, at the rear: 1 x 85 mm diameter
Internal dimensions: width 2000 mm, depth 570 mm, height 600 mm
External dimensions: width 3000 mm, depth 870 mm, height 1060 mm
Technical data:
Data for mechanical load:
max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Lsdezgbmiopfx Aavsac
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW, rated current 9 A
Fuse on customer side: 16A, slow-blow
Temperature testing chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement: sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi

















