Khử lưu huỳnh ở nhiệt độ thấp (DeSOx)
DeSOx System Low-temperature desulfurization

EXW VB VAT không thể hiển thị riêng biệt
1.364.000 €
Tình trạng
Đã qua sử dụng
Vị trí
Ostrava Cộng hòa Séc
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx) DeSOx System Low-temperature desulfurization
more Images
DeSOx System Low-temperature desulfurization
DeSOx System Low-temperature desulfurization
DeSOx System Low-temperature desulfurization
DeSOx System Low-temperature desulfurization
DeSOx System Low-temperature desulfurization
DeSOx System Low-temperature desulfurization
DeSOx System Low-temperature desulfurization
DeSOx System Low-temperature desulfurization
Hình ảnh cho thấy
Hiển thị bản đồ

Thông tin về máy móc

Tên máy:
Khử lưu huỳnh ở nhiệt độ thấp (DeSOx)
Nhà sản xuất:
DeSOx System
Mô hình:
Low-temperature desulfurization
Tình trạng:
đã qua sử dụng
Tính năng hoạt động:
hoạt động hoàn toàn

Giá & Vị trí

EXW VB VAT không thể hiển thị riêng biệt
1.364.000 €
Vị trí:
Ostrava, Czechia Cộng hòa Séc
Gọi điện

Chi tiết về đề nghị

ID tin đăng:
A19480486
Số tham chiếu:
DESOX
Cập nhật:
lần cuối vào ngày 02.07.2025

Mô tả

All data in enclosure passport.
Price on request.

Description:
Low-temperature desulfurization (DeSOx) system for boilers K8, K9, K10, and K11 at the heating plant operated by TAMEH Czech s.r.o. (now Vitkovice Energy s.r.o.).

Key Details:
Purpose: Removal of sulfur oxides (SOx) from flue gases at low temperatures.

Coverage: Installed on boilers K8, K9, K10, and K11.

1. Equipment description

1.1 Basic data and functional characteristics

The desulphurisation plant is used to reduce emissions of SO2 and particulate matter from the flue gases of boilers K8 (100 t/h steam), K9 (200 t/h steam), K10 (200 t/h steam), K11 (230 t/h steam). The desulphurisation building is connected to the outlets of the existing smoke fans behind the electrostatic precipitators of boilers K8 to K11 by new flue pipes.

The key component of the desulphurisation process, using the so-called semi-dry method, is the 2 vertical fluidised bed absorbers, consisting essentially of a large diameter high cylindrical upper section and a small diameter and much shorter cylindrical lower section, the two cylindrical sections being connected by a transition piece in the form of a venturi nozzle. The flue gas enters the absorber through the flue pipe where it is cooled to a temperature of about 80-105°C by water injection. The desulphurising agent calcium hydroxide Ca(OH)₂ is dosed into the absorber. In the absorber, the flue gases react with calcium hydroxide. After the reaction in the fluidised bed, the mixture of flue gas, fly ash and calcium hydroxide leaves the absorber and enters a fabric filter with four modules. Here, the flue gas is cleaned of any residual fly ash. The settled ash and dust residues in the filter media with the addition of reacted Ca(OH)₂ are called the desulphurisation product (unreacted, i.e. active Ca(OH)₂ in the product ranges from 4 - 12%, optimum up to 10%).

To ensure maximum availability, the desulphurisation plant has 2 absorbers. Each absorber is designed for 528,750 Nm³/h of dry flue gas, corresponding to 75% of the rated output, for a maximum inlet SO₂ concentration of [value missing]. For a lower inlet SO₂ concentration of up to 600 mg/Nm³, it is possible to operate one absorber with a flue gas quantity of 620,000 Nm³/h. For the quantity of flue gases to be desulphurised, see the following section.
This flue gas cleaning procedure is called semi-dry flue gas cleaning - the substances entering the absorber (calcium hydroxide and the return product) should not have a moisture content higher than 1.5%.

Equipment included:
Fluid absorbers 2x 620000Nm3/h
Silo CaO 450 m3
Silo Ca(OH)2 300 m3
Silo desulphurisation product 1000 m3
Scale fan 2x 240 m3/s
Compressor station main 3x 1398 m3/h
Backup compressor station 1x 310 m3/h
Absorption dryers 2x 1916 m3/h
Dieselagregate 80 kW
Pgodpfxswwt She Agzsu

Tài liệu

Nhà cung cấp

Lần truy cập cuối: tuần trước

Đã đăng ký từ: 2025

20 Quảng cáo trực tuyến

Gọi điện

Gửi yêu cầu

đấtus 
Đức
Áo
Thụy Sĩ
Hoa Kỳ
Vương quốc Liên hiệp Anh
Pháp
Bỉ
Tây Ban Nha
Mexico
Ý
Hà Lan
Ba Lan
Liên bang Nga
Belarus (Cộng hòa Belarus)
Ukraina
Estonia
Thổ Nhĩ Kỳ
New Zealand
Ai-len
Cộng hòa Séc
Đan Mạch
Phần Lan
Thụy Điển
Na Uy
Luxembourg
Hy Lạp
Litva
Latvia
Iceland
Bồ Đào Nha
Braxin
Venezuela
Argentina
Hungary
Slovakia
Rumani
Moldova
Slovenia
Serbia
Montenegro
Albania
Croatia
Bulgaria
Bắc Macedonia
Bosnia và Hercegovina
Israel
Ai Cập
Ma-rốc
Ấn Độ
Indonesia
Hàn Quốc
Nhật Bản
Thái Lan
Malaysia
Việt Nam
China
Đài Loan
Iran
Bangladesh
Afghanistan
Lưu ý: Yêu cầu của bạn sẽ được chuyển tới tất cả người bán trong danh mục máy móc. Nhờ vậy, bạn có thể nhận được rất nhiều lời đề nghị.
Không thể gửi yêu cầu. Vui lòng thử lại sau.

Điện thoại & Fax

+420 370 ... quảng cáo