Tủ kiểm tra nhiệt độ được bảo vệ trướcCTS
T-30/950 Ex/I
Tủ kiểm tra nhiệt độ được bảo vệ trước
CTS
T-30/950 Ex/I
Năm sản xuất
2011
Tình trạng
Đã qua sử dụng
Vị trí
Borken 

Hình ảnh cho thấy
Hiển thị bản đồ
Thông tin về máy móc
Giá & Vị trí
- Vị trí:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Gọi điện
Chi tiết về đề nghị
- ID tin đăng:
- A7538378
- Số tham chiếu:
- 23117
- Cập nhật:
- lần cuối vào ngày 27.06.2025
Mô tả
CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
Lajdpfxjihb Ame Ac Dok
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
Lajdpfxjihb Ame Ac Dok
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Tin đăng này được dịch tự động. Có thể có lỗi dịch thuật.
Nhà cung cấp
Lưu ý: Đăng ký miễn phí hoặc đăng nhập, để truy cập tất cả thông tin.
Đã đăng ký từ: 2012
Gửi yêu cầu
Điện thoại & Fax
+49 2861 ... quảng cáo
Những tin rao vặt này cũng có thể bạn quan tâm.
Quảng cáo nhỏ
Tata
8.866 km
Bình ngưng làm mát chất lỏng
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Quảng cáo nhỏ
Hochdorf
9.479 km
Bộ làm mát nhiệt độ (TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
Quảng cáo nhỏ
Berlin
9.112 km
Bộ ngưng tụ hướng trục
Güntner AGGVH 100.2A/2x3-J(D)
Güntner AGGVH 100.2A/2x3-J(D)
Quảng cáo nhỏ
Forst
9.528 km
Bể đệm 100 m³, 3 bar, cách nhiệt
Quảng cáo nhỏ
Delmenhorst
9.402 km
Lưu trữ bộ đệm bồn chứa áp suất 1000L
10539
10539
Quảng cáo nhỏ
Schmölln
9.215 km
Phòng lạnh
Dresdner Kühlanlagenbau
Dresdner Kühlanlagenbau
Quảng cáo nhỏ
Niedźwiedź
8.704 km
Đơn vị máy nén hai cấp
BitzerS6G-25.2Y (x4)
BitzerS6G-25.2Y (x4)
Quảng cáo nhỏ
Nattheim
9.425 km
Bảng điều khiển đứng cưa
Holz-Her1255
Holz-Her1255
Quảng cáo nhỏ
Borken
9.555 km
Buồng thử khí hậu có độ ẩm 1000 lít
CTSC-40/1000 -40°C bis +180°C
CTSC-40/1000 -40°C bis +180°C
Quảng cáo nhỏ
Wiefelstede
9.429 km
Hệ thống thông gió
HeimerWK-61
HeimerWK-61
Quảng cáo của bạn đã được xóa thành công
Đã xảy ra lỗi